Electrical Guides for Akron Homeowners

A breaker that will not stay on, a house to get ready for winter, a fuse box that may be due for replacement: each has a practical guide, written in plain words for the person who lives in the house.

Troubleshooting, Upkeep and Upgrade Choices

Homeowners can do a good deal safely: switch a tripped breaker back on once, press the test button on a GFCI outlet, note which outlets went dead and when. Opening the panel itself, or chasing a fault that keeps coming back, is where the job passes to an electrician.

A Starting Point for Each Situation

A sensible first step, taken before anyone opens a wall or a panel, often makes the rest of the job simpler and safer.

Swipe left to see the rest of the table.

Where to start, by situation
If you are dealing with Start with Link
A breaker that trips again after a reset Unplug what was running on that circuit, then switch the breaker back on once Tripping Breaker Troubleshooting
A dead outlet in a kitchen, bathroom or garage Look for a GFCI outlet nearby that has tripped, and press its reset button Repairs and Wiring
A house to get ready for winter or the storm season Test the GFCI outlets and the smoke and carbon monoxide alarms Seasonal Electrical Maintenance
A fuse box, or a panel with no open spaces List the large appliances you have now and the ones you plan to add Panel Upgrade Buyer’s Guide
A generator you want to use during outages Write down the circuits you would need, such as the furnace, sump pump and refrigerator Surge Protection and Generators
New lights or a ceiling fan Note where the switches are now and where you would want them Lighting Installation
A warm outlet, a burning smell or scorch marks Stop using it, and switch off that circuit if the panel is safe to reach Call (330) 526-3183

Electrical Terms in Plain Words

Estimates, inspection reports and the labels inside a panel door use words most people never need until something stops working. Search for one, or narrow the list to one part of the system.

Find an Electrical Term

Type part of a word, pick a category, or both.

Type a word or pick a category, then press Show Terms.

  • AFCI. Arc-fault circuit interrupter: a breaker or outlet that senses the arcing from a damaged cord, a loose connection or a nail through a cable, and shuts the circuit off.
  • Aluminum branch wiring. Aluminum wire used for outlet and light circuits in some houses from the mid-1960s to the early 1970s. Its connections can loosen and overheat, so repairs use connectors made for aluminum.
  • Amp. Short for ampere, the unit of electrical current. Wires, breakers and a home’s electrical service are all rated in amps.
  • Ampacity. How much current a wire can carry without overheating. A breaker is sized to protect its wire, so a larger breaker on a small wire defeats the point.
  • Back-feeding. Running generator power into the house wiring without a transfer switch or interlock, often through a cord in an outlet. It can put power on utility lines that crews expect to be dead.
  • Breaker. Short for circuit breaker: a switch in the panel that turns a circuit off by itself when it carries too much current or has a fault. Unlike a fuse, it can be reset.
  • Carbon monoxide alarm. An alarm that senses carbon monoxide, the odorless gas from fuel-burning equipment such as a furnace or water heater. It belongs outside the sleeping areas and on every level of the house.
  • Cloth-covered wiring. Cable with a woven cloth jacket over rubber insulation, common from about the 1920s into the 1960s. The rubber dries out and cracks with age, most of all inside hot light fixtures.
  • Color temperature. How warm or cool a light looks, measured in kelvin. About 2700 K is the warm white of an old incandescent bulb; 4000 K or higher looks cooler and bluer.
  • Dedicated circuit. A circuit that feeds one appliance alone, such as a refrigerator, a microwave, a furnace or an EV charger, so nothing else on it can cause an overload.
  • Dimmer compatibility. Whether a dimmer and the LED bulbs or fixtures it controls are made to work together. A poor match shows up as flicker, buzzing or uneven dimming.
  • Double-pole breaker. A double-width breaker that feeds a 240-volt circuit, for a dryer, range, water heater, air conditioner or EV charger.
  • Fan-rated box. A ceiling box made and marked to carry a ceiling fan’s weight and the pull of its motion, which an ordinary fixture box is not.
  • Fuse box. The older form of panel, with fuses in place of breakers, still found in many houses built before 1960. A fuse larger than the wire was meant for is a fire risk.
  • GFCI. Ground-fault circuit interrupter: an outlet or breaker that cuts the power in a fraction of a second when current leaks to ground. Pressing its test button should cut the power, and reset restores it.
  • Ground wire. The bare or green wire that gives a fault a safe path back to the panel, so the breaker trips instead of current passing through a person.
  • IC-rated recessed light. A recessed light made for direct contact with insulation, the kind a ceiling under an insulated attic needs.
  • Interlock kit. A sliding plate on the panel cover that lets the generator breaker go on only while the main breaker is off, so the two sources never meet.
  • Junction box. A covered box where wires are joined. Every splice belongs in one, with its cover on and within reach, never buried behind plaster or drywall.
  • Knob-and-tube. The earliest wiring method in American houses: single wires on porcelain knobs and tubes, with no ground wire and insulation that turns brittle with age and heat.
  • LED driver. The small power supply in an LED fixture or bulb that feeds the LEDs a steady, low-voltage current. A failing driver can make a light flicker or buzz.
  • Load calculation. A standard way of adding up what a house could draw at once. It shows whether the service has room for something new, such as a heat pump or an EV charger.
  • Lumens. A measure of how much light a bulb gives. With LEDs it is a better guide to brightness than watts: about 800 lumens matches an old 60-watt bulb.
  • Main breaker. The large breaker, usually at the top of the panel, that shuts off the whole house. The number on its handle usually matches the size of the service, such as 100 or 200 amps.
  • Meter base. The socket box on an outside wall that holds the meter. The meter belongs to the utility; the base is part of the house, and many service upgrades replace it.
  • Neutral. The wire, usually white, that carries current back to the panel. A loose neutral can make lights brighten and dim for no clear reason.
  • Pigtail. A short wire spliced to several others and attached to an outlet or switch, so the rest of the circuit does not depend on the device’s terminals.
  • Power inlet box. An outdoor box with a recessed plug for a portable generator’s cord, wired to a transfer switch or an interlocked panel inside.
  • Service drop. The overhead wires from the utility’s pole to the house, or buried cable for an underground service. For most of the Akron area, that utility is Ohio Edison.
  • Service entrance. Everything that carries power from the utility’s wires to the main panel: the weatherhead and mast, the meter base, and the heavy cable between them.
  • Smoke alarm interconnect. Wiring or a wireless link that makes every smoke alarm sound when one does, so a fire in the basement is heard behind a closed bedroom door upstairs.
  • Subpanel. A second, smaller panel fed from the main one, often in a garage, a workshop or an addition, so new circuits there need not run back to the main panel.
  • Surge protective device. A unit installed at the panel that diverts most of a voltage spike, from lightning or switching on the utility lines, before it reaches the house’s circuits.
  • Tamper-resistant outlet. An outlet with shutters behind the slots that open only when both prongs of a plug press in together, so a child cannot push a key or a hairpin inside.
  • Transfer switch. A switch beside or inside the panel that moves chosen circuits from utility power to a generator, so the two can never be connected at once.
  • Two-prong outlet. An outlet with no ground hole, usually on a circuit with no ground wire. It can be replaced with a GFCI outlet, or with a grounded outlet once a ground is run.

Before the Work Starts

Cost, permits and the first visit tend to come up early. The questions and answers on electrical work take them a topic at a time, from getting started to inspections.

Some Problems Need Testing

Reading narrows a problem down; testing the circuits involved settles it, and a call is the simplest way to arrange that.